EqLifeBand
WEARABLE
A rugged wearable device that monitors vital signs in real time, ensuring safety for soldiers, construction workers, and high-risk professionals through continuous health tracking and timely alerts.
Project under
InventIndia Innovations, IN
Client
Equivital, UK
THE CHALLENGE
Heat stress causes thousands of workplace deaths every year, hitting construction, manufacturing, mining, and military training hardest. Existing vital-monitoring armbands (Kenzen, SlateSafety, Biovotion, Polar, Whoop) are uncomfortable for the long, physically demanding shifts these workers actually do.
400+ heat-related workplace deaths since 2011 - U.S. Bureau of Labor Statistics
The Process
START — PILOT BATCH
From defining the goals to the pilot batch, in order.
Explore
Prototype
Refine
Validate
Research
01
02
Concept Exploration
Product Architecture
03
04
POC — EVT
Form Development
05
06
Final Device Design
Material testing
Strap Design
07
08
Chargers Design
T-1 Samples
09
10
Pilot Batch - DVT
Design Goals
Five components had to work together as one system - the wearable, its strap, and the charging infrastructure behind it.
01
Vital Monitoring Device
Worn on the upper arm with PPG-based tracking, lightweight, discreet, and comfortable for long-term wear.
02
Detachable Arm Strap
Attaches and detaches easily from the body, breathable for comfort, built to ATEX material standards.
03
ATEX Compliant
Fully rated for hazardous environments with explosive gas or dust, with intrinsically safe components.
04
Single Dock Charger
A compact, precise charging dock that aligns the device automatically for effortless daily charging.
05
Multi-Dock Charger
Charges up to 25 devices at once ,organized, secure, and built for clinical or industrial settings.
Concept Exploration
Two attachment mechanisms were explored side by side, then the enclosure architecture was optimized around whichever proved sleekest to build.
Spring Release Mechanism
A spring-loaded plunger grips a lip in the cavity; a leaf-spring trigger releases the device with a single press.

Bayonet Mechanism
Flanges align and twist to lock firmly in place, with a reverse twist for easy removal and a positive end-rotation lock.

Product Architecture
Three product architectures were explored to test different internal volumes and integrate the two shortlisted attachment mechanisms - each pushed toward the sleekest possible enclosure. A dimension evaluation across the candidates landed the final build at 13.50mm thick, shaving nearly half a millimeter off the bulkiest option.

POC - EVT
A batch of 12 devices was made for EVT phase.

Hand injection molding was used to make 20 pieces for testing purposes. Injection molding was chosen to ensure sufficient strength for the bayonet mechanism. 3D printed becomes quite brittle.



Form development
Different packages were explored for volumetric breakdown. The main idea was to make the device look as sleek as possible, perceptually. The internal assembly across all the mockups was the same.






Final Device Design
06 - 10
After the testing phase of initial EVT prototypes, the final Industrial Design round was done, and this design concept was taken forward.


Strap Design
Seven clasping and perforation variants were cut and refined from the winning strap concept, then hand-built into wearable POC1 units in the workshop so the earliest device prototypes had something to strap on.

Strap, Tooling & Validation
Engineering and tooling support then carried the design through T0 and T1 sample rounds, coordinating directly with tooling vendors to validate fit and function, before a 60-piece pilot batch was cast from 3 vacuum-cast moulds for field testing.
In-house prototype


24-hour wear trial across 9 participants: 89% reported no discomfort from the module, and 100% never felt the need to switch arms
Prototypes at vendor’s

CNC Mockup
A CNC-machined dummy prototype was built to closely resemble the final product’s form and feel, giving visitors a hands-on experience at the American Industrial Hygiene Association (AIHA) exhibition booth.



Single dock charger ID
Multiple different types of architectures were built before coming down to this architecture with a base engulfing the device from all sides except top, to keep it safe from vibrations and physical movements. These are the 4 shortlisted variations of final industrial design tweaks.




Charging System
Two dedicated docks round out the system: a single-unit charger for everyday use, and a 25-slot dock for clinical or industrial fleets that need to charge and organize devices at scale.
Single Dock Charger
A compact, stable dock with a precise, secure fit - designed to make daily charging effortless.



Multi-Dock Charger
Charges up to 25 devices at once with organized, secure slots - compact yet robust for daily fleet use.

Each dock self-aligns magnetically - N52 magnets seated in the dock pull against metal pieces inside the device, so the pogo-pin contacts land correctly every time.
T-1 device samples
First batch was made for the top and bottom enclosure was made for part accuracy evaluation, as well as sink marks or flow marks. We observed a couple of things like the light guide fitment, bayonet mechanism working and ultrasound welding before going into the texture of the tool.